GUIDE PRESCRIBING THE SCOPE OF WORK OF THE « INTERIOR SYSTEMS» SPECIALTY

This guide must be used in accordance with the guidelines.

The tender must relate to architectural, interior design and structural tendering documents

  1. IS. 1 - Supply and installation :
     
    1. Marking of interior system work;
       
    2. Bearing and non-bearing metal studs;
       
    3. Metal studs for parapets;
       
    4. Metal girts and sub-girts such as metal furring, horizontal bars and Z-bars, U-bars, L-bars or others, supporting the interior systems;
       
    5. Backing (wood, steel or other);
       
    6. Pre-fabricated acoustic panels installed on walls and ceilings, except if under the woodworking, carpentry or millwork sections;
       
    7. Soundproofing panels, such as «Sonopan»; 
       
    8. Gypsum or lightweight interior cement boards, treatment of joints and plaster work ready for finishing;
       
    9. Lightweight exterior cement boards and Gyplap, DensGlass Gold panels and other similar sheating panels found on units listed in IS 1.2, IS 1.3 and IS 1.4;
       
    10. Panels without laminated air/vapour barrier membrane insulation;
       
    11. Frame of suspended ceiling (for gypsum, acoustic tiles, caissons, etc.);
       
    12. Ceilings, such as slat ceilings, stretch fabric ceilings and acoustic tile ceilings;
       
    13. Patch and repair of interior systems, as quantified or if included in the above-mentioned tendering documents;
       
    14. Plastering, including of heritage structures;
       
    15. Mouldings and columns, precast or not, with plaster covering;
       
    16. Rigid interior insulation covered with gypsum or cement board with integrated “Insulock” or other support;
       
    17. Soundproofing wool batt;
       
    18. Thermal wool and semi-rigid batt in metal studs, including those in ceilings, beams and columns;
       
    19. Vapour barrier in the wall and ceiling on the interior side of the metal frame;
       
    20. Sheet or roll lead in the walls and ceilings for acoustic or medical (radiology) purposes, etc.;
       
    21. All sealing for interior systems work, including those for the structural frame.
       
  2. IS. 2 – Installation only :
     
    1. Steel frames welded and secured to metal studs, including their handling from the installation floor.
       
  3. IS. 3 - Work specifically excluded :
     
    1. Sprayed and/or injected thermal or acoustic insulation, such as mineral fibre, fibreglass and cellulose fibre;
       
    2. Steel frames assembled at the worksite;
       
    3. Temporary partition walls to be removed at the end of the project;
       
    4. Lightweight concrete board with acrylic coating, which is included under the acrylic coating section of the specifications;
       
    5. Fire-retardant sealers of other specialties; 
       
    6. Backing on the outside of the building envelope (walls, parapets and roofs);
       
    7. Backing on the openings of the building envelope;
       
    8. Plywood finish on the surface of interior system panels;
       
    9. Backing on wood studs.