It should be noted that, for interpretation purposes, the French text shall prevail over the English, the latter being a translation of the French original.
GUIDE PRESCRIBING THE SCOPE OF WORK OF THE « THERMAL INSULATION‒OTHER THAN ROOFING OR MECHANICAL» SPECIALTY
This guide must be used in accordance with the guidelines.
The tender must be based on architectural, interior design and structural tendering documents
- TI. 1 - Supply and installation :
- Rigid and semi-rigid insulation, including under slabs, on ground and on foundation walls;
- Sprayed and/or injected thermal or acoustic insulation, such as mineral fibre, fibreglass and cellulose fibre;
- Flexible flashing, air barrier, vapour barrier and air/vapour barrier;
- Urethane foam insulation, sprayed or injected;
- Retaining sheets for flexible flashing;
- Mechanical fastening for items under TI article 1.3.
- TI. 2 - Work specifically excluded :
- Mechanical insulation;
- Roof and awning insulation and membrane;
- Membranes, vapour barrier, air barrier and air/vapour barrier for parapets;
- Soundproofing wool (batt or semi-rigid);
- Thermal wool (batt);
- Vapour barrier in the wall and ceiling on the interior side of the frame;
- Insulation and membranes of curtain wall systems;
- Insulation and membranes of composite and sandwich walls;
- Panels without laminated air/vapour barrier membrane;
- Steel girts and sub-girts such as steel furring, horizontal bars and Z-bars, U-bars, Lbars or others;
- Rigid interior insulation covered with gypsum or cement board with integrated “Insulock” or other support;
- Foundation waterproofing such as membranes, water repellents and others;
- Insulation directly installed on foundation waterproofing system such as membranes, water repellents and others;
- Monocomponent urethane seal around openings;
- Installation of insulation in formwork before concrete pour;
- Formwork insulation;
- Insulation for acrylic coating system.
Updated: May 1st 2021